• head_banner_01

Phoenix Contact 2966676 PLC-OSC- 24DC/ 24DC/ 2/ACT - Modil relè eta solid

Deskripsyon kout:

PHOENIX Kontakte 2966676is PLC-ENTERFACE pou fonksyon pwodiksyon, ki gen ladann PLC-BSC.../ACT blòk tèminal debaz ak koneksyon vis ak relè miniature eta solid, pou aliye sou tren DIN NS 35/7,5, 1 N/O kontak, antre. : 24 V DC, pwodiksyon: 3 - 33 V DC / 3 A


Pwodwi detay

Tags pwodwi

Dat Komèsyal

 

Nimewo atik 2966676
Anbalaj inite 10 pc
Minimòm kantite lòd 1 pc
Komèsyal kle CK6213
Kle pwodwi CK6213
Paj katalòg Paj 376 (C-5-2019)
GTIN 4017918130510
Pwa pou chak moso (ki gen ladan anbalaj) 38.4 g
Pwa pou chak moso (eksepte anbalaj) 35.5 g
Nimewo tarif Ladwàn yo 85364190
Peyi orijin DE

Deskripsyon pwodwi

 

Nominal D' vòltaj UN 24 V DC
Ranje vòltaj Antre an referans a Nasyonzini 0.8 ... 1.2
Ranje vòltaj Antre 19.2 V DC ... 28.8 V DC
Chanje siyal papòt "0" an referans a Nasyonzini ≤ 0.4
Chanje siyal papòt "1" an referans a Nasyonzini ≥ 0.8
Kouran opinyon tipik nan Nasyonzini 8.5 mA
Tan repons tipik 20 µs (nan UN)
Tan tipik fèmen 300 µs (nan UN)
Ekspozisyon vòltaj opere Dirije jòn
Sikwi pwoteksyon Pwoteksyon polarite ranvèse; Dyòd pwoteksyon polarite
Dyòd freewheeling; Dyòd freewheeling
frekans transmisyon 300 Hz

 

 

Done pwodiksyon

Kontak chanje kalite 1 N/O kontak
Konsepsyon pwodiksyon dijital elektwonik
Kontakte kalite koneksyon Kontak pouvwa
Ranje vòltaj pwodiksyon 3 V DC ... 33 V DC
Limite aktyèl kontinyèl 3 A (gade koub derating)
Maksimòm inrush aktyèl 15 A (10 ms)
Gout vòltaj nan max. limite kouran kontinyèl ≤ 200 mV
Sòti sikwi 2-kondiktè, k ap flote
Sikwi pwoteksyon Pwoteksyon polarite ranvèse; Dyòd pwoteksyon polarite
Pwoteksyon vag

 

 

Done koneksyon

Metòd koneksyon Koneksyon vis
Longè retire rad sou ou 8 mm
Fil vis M3
Kondiktè koup transvèsal rijid 0.14 mm² ... 2.5 mm²
Seksyon transvèsal kondiktè fleksib 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (yon sèl férule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Kondiktè koup transvèsal AWG 26 ... 14
Sere koupl 0.6 Nm ... 0.8 Nm

  • Previous:
  • Pwochen:

  • Ekri mesaj ou la a epi voye l ba nou

    Pwodwi ki gen rapò

    • Phoenix Contact 2908341 ECOR-2-BSC2-RT/2X21 - baz relè

      Phoenix Contact 2908341 ECOR-2-BSC2-RT/2X21 - R...

      Dat Komèsyal Nimewo atik 2908341 Inite anbalaj 10 pc Kle lavant C463 Kle pwodwi CKF313 GTIN 4055626293097 Pwa pou chak moso (ki gen ladan anbalaj) 43,13 g Pwa pou chak moso (eksepte anbalaj) 40,35 g Ladwàn nimewo tarif orijin CN9 853 Relay nan fyab nan Phoenix669 CN9 853. ekipman automatisation ap ogmante ak...

    • Phoenix Contact 2910588 ESSENTIAL-PS/1AC/24DC/480W/EE - Inite ekipman pou pouvwa

      Phoenix Contact 2910588 ESSENTIAL-PS/1AC/24DC/4...

      Dat Komèsyal Nimewo Atik 2910587 Inite anbalaj 1 PC Kantite minimòm lòd 1 PC Kle lavant CMP Kle pwodwi CMB313 GTIN 4055626464404 Pwa pou chak moso (ki gen ladan anbalaj) 972.3 g Pwa pou chak moso (eksepte anbalaj) 800 g Nimewo Ladwàn orijin408550 Peyi ou 40855. Teknoloji SFB vwayaje estanda disjoncteurs sele...

    • Phoenix Contact 2910586 ESSENTIAL-PS/1AC/24DC/120W/EE - Inite ekipman pou pouvwa

      Phoenix Contact 2910586 ESSENTIAL-PS/1AC/24DC/1...

      Dat Komèsyal Nimewo Atik 2910586 Inite anbalaj 1 PC Kantite minimòm lòd 1 PC Kle lavant CMP Kle pwodwi CMB313 GTIN 4055626464411 Pwa pou chak moso (ki gen ladan anbalaj) 678.5 g Pwa pou chak moso (eksepte anbalaj) 530 g Nimewo Ladwàn ki gen orijin nan408550. Teknoloji SFB vwayaje estanda disjoncteurs sele...

    • Phoenix Contact 2866381 TRIO-PS/ 1AC/24DC/20 - Inite ekipman pou pouvwa

      Phoenix Contact 2866381 TRIO-PS/ 1AC/24DC/20 - ...

      Dat Komèsyal Nimewo Atik 2866381 Inite anbalaj 1 PC Kantite minimòm lòd 1 PC Kle lavant CMPT13 Kle pwodwi CMPT13 Paj katalòg Paj 175 (C-6-2013) GTIN 4046356046664 Pwa pou chak moso (ki gen ladan anbalaj) 2,354 g, san konte 204 moso) g Nimewo tarif Ladwàn 85044095 Peyi orijin CN Product description TRIO ...

    • Phoenix Contact 2909575 QUINT4-PS/1AC/24DC/1.3/PT - Inite ekipman pou pouvwa

      Phoenix Contact 2909575 QUINT4-PS/1AC/24DC/1.3/...

      Deskripsyon pwodwi Nan seri pouvwa ki rive jiska 100 W, QUINT POWER bay disponiblite siperyè sistèm nan gwosè ki pi piti a. Siveyans fonksyon prevantif ak rezèv pouvwa eksepsyonèl yo disponib pou aplikasyon nan seri a ba-pouvwa. Dat Komèsyal Nimewo Atik 2909575 Inite anbalaj 1 pc Kantite lòd minimòm 1 pc Kle lavant CMP Kle pwodwi ...

    • Phoenix Contact 2904598 QUINT4-PS/1AC/24DC/2.5/SC - Inite ekipman pou pouvwa

      Phoenix Contact 2904598 QUINT4-PS/1AC/24DC/2.5/...

      Deskripsyon pwodwi Nan seri pouvwa ki rive jiska 100 W, QUINT POWER bay disponiblite siperyè sistèm nan gwosè ki pi piti a. Siveyans fonksyon prevantif ak rezèv pouvwa eksepsyonèl yo disponib pou aplikasyon nan seri a ba-pouvwa. Dat Komèsyal Nimewo Atik 2904598 Inite anbalaj 1 pc Kantite minimòm lòd 1 pc Kle lavant CMP Kle pwodwi ...